DC/DC Front-End Modules
Simplifying your future
GAIA Converter offers a complete range of Front-End elements to protect and adapt the power conversion stage. These Front-End Modules are designed to allow power engineers to ease the development of complex architectures and decrease the time-to-market of projects.
The Front-End performs input filtering and shaping of the input network, including the following functions:
- EMI filter
- Reverse polarity
- Surge limiter
- Under voltage limiter
- Inrush current limitation
- Hold up: Transparency during momentary input bus interruptions – drop outs
- On/Off
- Supply of additional signals to ensure perfect power supply management
GAIA Converter offers different types of modules as follows:
Multi function front-end modules
Single function modules
- The “Input Bus conditioners” GAIA modules integrate one or more functions of DC/DC Front End like
EMI filter, reverse polarity, surge limiter, under voltage limiter, inrush current limitation, hold-up: transparency during momentary input bus drop-outs, On/Off, supply of complentary signals to ensure perfect management of power supply
GAIA Converter offers 4 Input Bus Conditioner product lines:
- Limiter modules (LGDS Series) whose main function is the limitation of high voltage transients
- Pre-regulated modules (PGDS Series) whose main function is to reduce low voltage and high voltage transients
- Modules (LHUG) whose main functions, among others, are reverse polarity protection limitation of high voltage transients and Hold Up
- Modules (FLGH Series) whose main functions, among others, are EMI filtering, reverse polarity protection limitation of high voltage transients and Hold Up
Input Bus Conditioners Series
Series | Grade | Data Sheets | Output power | RoHS / SnPb | Input voltage | Max transient input voltage | Min transient input voltage | Output voltage | Output current | GAIA Overall package | Charger power | Power dissipation | EMI Filter | Spike protection | Reverse polarity | On/Off | Output transient limiter | Hold-up | Transient elevator | Synchronization | Hold-up thres. voltage | Standard electrical functions |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
|
|
|
|||||||||||||||||
FLHG-60 | 60W | (M) : 10.7 - 100 Vdc | (M) : N/A | (M) : 11.2 Vdc / | [S] 80 Clamp Vdc | 0.75 A 3.75 A 5.5 / 30 A/s | 2.0-1.6-0.5 | MIL-STD-461 | N | Y | Y | Y | Y | N | N | |||||||
FLHGI-90 | 90 W | (R) : 12 - 140 Vdc | (R) : 385 Vdc / 20 ms | (R) : N/A | [S] 12 - 140 Vdc | 0.9 A 4 A | 2.0-1.6-0.5 | 6 W | EN 55121, EN-55022 | N | Y | Y | Y | Y | N | OUT | ||||||
LGDS-100 | 100 W | (P) : 202 Vdc / 350 ms | (P) : 7 Vdc / 1 s | [S] 9 - 42 Vdc | 10 A | 1.6-1.0-0.5 | Basic | N | N | N | Y | N | N | N | ICL, OCP, OTP | |||||||
LGDS-300 | 300 W | (O) : 100 Vdc / 50 ms | (O) : 7 Vdc / 1 s | [S] 9 - 42 Vdc | 20 A | 1.6-1.0-0.5 | 3 W | Basic | N | N | N | Y | N | N | N | ICL, OCP, OTP | ||||||
LGDS-600 | 600 W | (O) : 9 - 36 Vdc (P) : 9 - 36 Vdc | (O) : 100 Vdc / 50 ms (P) : 202 Vdc / 350 ms#Output disconnected | (O) : N/A (P) : N/A | [S] 38 +/- 1 Vdc | 35 A | 2.0-1.6-0.5 | 15 W 2.5 W 5 W 7.5 W | Basic | N | Y | Y | Y | N | N | Y | ||||||
LGDSI-50 | 50 W | (J) : 10 - 36 Vdc (Q) : 36 - 154 Vdc | (J) : 85 Vdc / 20 ms (Q) : 385 Vdc / 20 ms | (J) : N/A (Q) : N/A | [S] 40 max Vdc | 1.78 A | 1.6-1.0-0.5 | EN-55022 | Y | Y | Y | Y | N | N | N | ON/OFF, REV.POL | ||||||
LGDSI-75 | 75 W | (Q) : 165 Vdc / 1 s | (Q) : N/A | [S] 40 max Vdc | 1.78 A | 1.6-1.0-0.5 | EN-55022 | Y | Y | Y | Y | N | N | N | ON/OFF, REV.POL | |||||||
LHUG-150 | 150 W | (M) : 11- 80 Vdc | (M) : 100 Vdc / 50 ms | (M) : N/A | [S] 78 max Vdc | 10 A | 1.6-1.25-0.3 | 17 W | 13 W | MIL-STD-461 | N | Y | Y | Y | Y | N | IN/OUT | UVLO, OPP, SYNC, PF, REV.POL | ||||
PGDS-50 | 50 W | (N) : 17 - 37 Vdc (O) : 12 - 37 Vdc | (N) : 80 Vdc / 100 ms (O) : 100 Vdc / 50 ms | (N) : 10 Vdc / 30 s (O) : 6 Vdc / 1 s | [S] 9 - 36 Vdc | 1.6-1.0-0.3 | Basic | N | Y | Y | Y | N | Y | N | UVLO, ON/OFF | |||||||
No data |
Values of Inputs: each value is associated to the GAIA Converter code (between brackets)
Values of Outputs: each value is associated to Output Number (between brackets)
GAIA overall package: GAIA specific designation based on dimensions in inches with a tolerance around ± 10% – Consult DataSheet for precise dimensions
Standard electrical functions: Case: Case connection, OVLO: Input overvoltage lockout, UVLO: Input under voltage lockout, OCP: Output over current protection level, OPP: Output over power protection, OVP: Output over voltage protection level, SCP: Output short circuit protection, OTP: Over temperature protection, VIF: Pin for Input Current Ripple Reduction, SYNC: Pin for Synchronisation, TRIM: Pin for adjust ouput voltage, ITRIM: Pin for adjustement ouput current limitation, CC: Pin for capacitor charged signal, CD: Pin for capacitor discharged signal, UVLOadj: Pin for level undervoltage lockout adjust, VREF: Pin for output internal voltage reference, PF: Pin for power fail signal, SENSE: Pin for voltage regulation, REV.POL: Reverse polarity protection, SHARE: Pin for output current parallel sharing
Options: T Screening at start-up -55° C, Y High isolation 3000 Vdc, M On/Off function, S Screening and serialization, F Synchronization function, P Share function
GAIA Converter proposes a full family of state-of-the-art EMI filter modules to fulfill Electromagnetic Interferences (EMI) requirements for Aerospace/Defense applications in a very compact and low loss solution for applications requiring up to 35 amps of input current.
Our EMI Filter modules will help your power supply comply with major standards (MIL-STD-461 rev C, D, E and F – DO-160 rev C, D, E F and G).
All High-Rel filter performances are met across severe environments and operating temperatures of -40°C/+105°C (-55°C also available), and operating and storage temperatures of -55°C/+125°C.
The 100V filter range incorporates an inrush current limiter for the capacitors integrated in the filter. Combined with the “Input Bus Conditioners” modules, they allow the overall architecture of the power supply to respect the current inrush limits imposed by the D0160 and ABD100 standards.
EMI Filters Series
Series | Grade | Data Sheets | Output power | RoHS / SnPb | Input voltage | Output current | GAIA Overall package | DC resistance | Standard electrical functions |
---|---|---|---|---|---|---|---|---|---|
|
|
|
|||||||
FGDS-2A-50V | 2 A - 50 V | 9 - 50 Vdc | 2 A | 1.25-0.8-0.4 | 80 mOhm | ||||
FGDS-6A-100V | 6 A - 100 V | 4.5 - 100 Vdc | 6 A | 1.0-0.8-0.3 | 30 mOhm | ICL | |||
FGDS-10A-50V | 10 A - 50 V | 9 - 50 Vdc | 10 A | 1.6-1.0-0.5 | 11 mOhm | ||||
FGDS-12A-100V | 12 A - 100 V | 4.5 - 100 Vdc | 12 A | 1.25-1.0-0.3 | 30 mOhm | ICL | |||
FGDS-20A-50V | 20 A - 50 V | 9 - 50 Vdc | 20 A | 1.6-1.0-0.65 | 5 mOhm | ||||
FGDS-35A-50V | 35 A - 50 V | 9 - 50 Vdc | 35 A | 1.6-1.0-0.65 | 5 mOhm | ||||
FGDS-35A-100V | 35 A - 100V | 35 A | 1.6-1.0-0.65 | 5 mOhm | |||||
No data |
Values of Inputs: each value is associated to the GAIA Converter code (between brackets)
Values of Outputs: each value is associated to Output Number (between brackets)
GAIA overall package: GAIA specific designation based on dimensions in inches with a tolerance around ± 10% – Consult DataSheet for precise dimensions
Standard electrical functions: Case: Case connection, OVLO: Input overvoltage lockout, UVLO: Input under voltage lockout, OCP: Output over current protection level, OPP: Output over power protection, OVP: Output over voltage protection level, SCP: Output short circuit protection, OTP: Over temperature protection, VIF: Pin for Input Current Ripple Reduction, SYNC: Pin for Synchronisation, TRIM: Pin for adjust ouput voltage, ITRIM: Pin for adjustement ouput current limitation, CC: Pin for capacitor charged signal, CD: Pin for capacitor discharged signal, UVLOadj: Pin for level undervoltage lockout adjust, VREF: Pin for output internal voltage reference, PF: Pin for power fail signal, SENSE: Pin for voltage regulation, REV.POL: Reverse polarity protection, SHARE: Pin for output current parallel sharing
Options: T Screening at start-up -55° C, Y High isolation 3000 Vdc, M On/Off function, S Screening and serialization, F Synchronization function, P Share function
The HUGD Series
GAIA Converter Hold-up devices are an alternative solution to the use of batteries or bulk capacitors to negate problems related to momentary input bus drop-outs.
The GAIA Converter HUGD series provides an alternative solution to reduce the amount of capacitance needed by charging the hold-up capacitor at a high voltage value. The device is connected between the input line source bus and DC/DC modules.
Hold-Up Series
Series | Grade | Data Sheets | Output power | RoHS / SnPb | Input voltage | Output current | GAIA Overall package | Hold-up thres. voltage | Max. output V x I | Standard electrical functions |
---|---|---|---|---|---|---|---|---|---|---|
|
|
|
|
|||||||
HUGD-50 | 50 W | 5.6 A | 1.6-1.0-0.5 | 9.5 to 15.3 Vdc | 50 W | CC, CD, PF, REV.POL | ||||
HUGD-300 | 300 W | max. 30 A | 1.6-1.0-0.5 | Adj. 6 to 20 Vdc | 300 W | CC, CD, PF, REV.POL | ||||
No data |
Values of Inputs: each value is associated to the GAIA Converter code (between brackets)
Values of Outputs: each value is associated to Output Number (between brackets)
GAIA overall package: GAIA specific designation based on dimensions in inches with a tolerance around ± 10% – Consult DataSheet for precise dimensions
Standard electrical functions: Case: Case connection, OVLO: Input overvoltage lockout, UVLO: Input under voltage lockout, OCP: Output over current protection level, OPP: Output over power protection, OVP: Output over voltage protection level, SCP: Output short circuit protection, OTP: Over temperature protection, VIF: Pin for Input Current Ripple Reduction, SYNC: Pin for Synchronisation, TRIM: Pin for adjust ouput voltage, ITRIM: Pin for adjustement ouput current limitation, CC: Pin for capacitor charged signal, CD: Pin for capacitor discharged signal, UVLOadj: Pin for level undervoltage lockout adjust, VREF: Pin for output internal voltage reference, PF: Pin for power fail signal, SENSE: Pin for voltage regulation, REV.POL: Reverse polarity protection, SHARE: Pin for output current parallel sharing
Options: T Screening at start-up -55° C, Y High isolation 3000 Vdc, M On/Off function, S Screening and serialization, F Synchronization function, P Share function